COC TOPAS® 8007-F400 JAPAN POLYPLASTIC
131
- Unit Price:
- $11537 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 15.5MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Dimensional stability Chemical resistance
- Application Areas:LCD application Optical applications
- Color:--
- Grade:Thin film grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Water absorption rate | (23°C,24hr) | ISO62 | 0.01 | % |
Melt flow index | 260℃/2.16Kg | ISO1133 | 32 | cm3/10min |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
tensile strength | 23°C | ISO527-2 | 63 | Mpa |
elongation at break | 23°C | ISO527-2 | 4.5 | % |
Tensile modulus | 23°C | ISO527-2 | 2600 | Mpa |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 2.6 | kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 20 | kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 0.45MPaUnannealed | ISO75-2/Bf | 75 | °C |
Vicat softening temperature | ISO306/B50 | 80 | °C | |
玻璃转化温度 | ISO11357-2 | 78 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Volume resistance | IEC60093 | 1E+14 | Ω.cm | |
Dielectric constant | 23°C | IEC60250 | 2.35 | 1kHz |
Dissipation factor | 相对漏电起痕指数 | IEC60112 | 600 | V |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Refractive index | ISO489 | 1.53 | °C | |
Transmittance 2000 μ m | ISO13468-2 | 91 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.