TPE Arnite®  EM630 DSM HOLAND

120
  • Unit Price:
    $6745 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    10MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Thermal stability
  • Application Areas:--
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Apparent densityISO 600.76g/cm³
Molten Volume Flow Rate (MVR)230°C/2.16 kgISO 11334.00cm3/10min
Water absorption rateSaturation, 23°CISO 620.60%
Water absorption rateEquilibrium, 23°C, 50% RHISO 620.20%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulusISO 527-2280Mpa
Tensile stressYieldISO 527-222.0Mpa
Tensile stressBreakISO 527-231.5Mpa
Tensile stress5.0% StrainISO 527-212.5Mpa
Tensile stress10% StrainISO 527-218.0Mpa
Tensile stress50% StrainISO 527-221.0Mpa
Tensile stress100% StrainISO 527-222.0Mpa
Tensile stress300% StrainISO 527-220.0Mpa
Tensile strainYieldISO 527-229%
Tensile strainBreakISO 527-2> 300%
Nominal tensile fracture strainISO 527-2> 50%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Vicat softening temperatureISO 306/B50125°C
Melting temperature 3ISO 11357-3212°C
Linear coefficient of thermal expansionFlowISO 11359-21.9E-4cm/cm/°C
Linear coefficient of thermal expansionAcross FlowISO 11359-21.9E-4cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistivityIEC 600931.0E+14ohms·cm
Dielectric strengthIEC 60243-122KV/mm
Relative permittivity100 HzIEC 602503.80
Relative permittivity1 MHzIEC 602503.40
Dissipation factor100 HzIEC 602500.011
Dissipation factor1 MHzIEC 602500.034
Leakage Trace IndexIEC 60112600V
hardnessTest ConditionTest MethodTest ResultUnit
Shore hardnessShore D, 3 secISO 86860
flammabilityTest ConditionTest MethodTest ResultUnit
Flammability level1.6 mmIEC 60695-11-10, -20HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.