Need Help? Contact Us service@plas.com
Get App

PA12 Pebax® Rnew® 70R53 SP 01 ARKEMA FRANCE

153
  • Unit Price:
    $13339 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    71.6MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:High temperature resistan Low temperature resistanc
  • Application Areas:Medical Supplies
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateAcross FlowISO 294-41.2%
Shrinkage rate流量ISO 294-41.3%
Water absorption rateSaturation, 23°CISO 621.0%
Water absorption rateEquilibrium, 23°C, 50% RHISO 620.70%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulusISO 527-2--Mpa
Tensile stressYieldISO 527-2--Mpa
Tensile stress300% StrainISO 527-257.0Mpa
Tensile strainYieldISO 527-2--%
Tensile strainBreakISO 527-2> 300%
Nominal tensile fracture strainISO 527-2--%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Vicat softening temperatureISO 306/B50175°C
Melting temperature 2ISO 11357-3186°C
Melting temperature 2Renewable Carbon ConentCSA LISTED87 到 91%
injectionTest ConditionTest MethodTest ResultUnit
drying temperature70 到 80°C
drying time5.0 到 7.0hr
Processing (melt) temperature230 到 290°C
Mold temperature25 到 60°C
squeezeTest ConditionTest MethodTest ResultUnit
drying temperature70 到 80°C
drying time5.0 到 7.0hr
Melt Temperature 220 到 250°C
Impact performanceTest ConditionTest MethodTest ResultUnit
Impact strength of simply supported beam without notch-30°CISO 179/1eU--
Impact strength of simply supported beam without notch23°CISO 179/1eU--
hardnessTest ConditionTest MethodTest ResultUnit
Supporting hardnessShore D, 15 secISO 7619-162
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.