PPS DURAFIDE® 6465A6 DAICEL MALAYSIA
195
- Unit Price:
- $5696 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 39.5MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:High temperature resistan High gloss Flame retardant Glass fiber reinforced enhance
- Application Areas:Household appliances Fiber grade
- Color:--
- Grade:Enhanced level
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Water absorption rate | 23℃,24hr 23℃,24 hr | ISO 62 | 0.03 | % |
Apparent viscosity of melt | 310℃,1000 sec^-1 310℃,1000 sec^-1 | ISO 11443 | 280000 | mPa·s |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile strength | ISO 527-2 | 140 | Mpa | |
Tensile strain | Break Break | ISO 527-2 | 1 | % |
Bending modulus | ISO 178 | 19000 | Mpa | |
bending strength | ISO 178 | 200 | Mpa | |
Rockwell hardness | M-Scale M-Scale | ISO 2039-2 | 105 |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Color Number Color Number | HD9050 |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Volume resistivity | IEC 60093 | 2000000000000000 | ohms·cm | |
Dielectric strength | 3 mm 3.00 mm | IEC 60243-1 | 15 | KV/mm |
Relative permittivity | 1 kHz 1 kHz | IEC 60250 | 4.8 | |
1 MHz 1 MHz | IEC 60250 | 4.8 | ||
Dissipation factor | 1 kHz 1 kHz | IEC 60250 | 0.002 | |
1 MHz 1 MHz | IEC 60250 | 0.002 | ||
Arc resistance | 170 | sec | ||
Compared to the leakage trace index | IEC 60112 | 175 | V |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of simply supported beam gap | 23℃ 23℃ | ISO 179/1eA | 6 | kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Flame retardant grade | UL 94 | V-0 |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Linear coefficient of thermal expansion | TD TD | 内部方法 | 0.000030 | 1/℃ |
MD MD | 内部方法 | 0.000010 | 1/℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.