Material Description
Technical Data Sheet

Material Description

  • Material Properties:Glass fiber reinforced Flame retardant wear resistant
  • Application Areas:Fiber grade
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Density/specific gravityISO 11831.95g/cm³
Mold shrinkage rateISO 25770.2-0.6%
Shrinkage rateTDASTMD9550.30to0.50%
Shrinkage rateTDISO294-40.30to0.70%
Shrinkage rateMDISO294-40.20to0.60%
Water absorption rateSaturation,23°CISO620.020%
SpiralFlow内部方法15.5
Density/specific gravityASTMD7922.00g/cm³
Specific volumeASTMD7920.502cm³/g
Density/specific gravityISO11831.95g/cm³
Melt mass flow rateASTMD12387.5g/10min
Shrinkage rateMDASTMD9550.10to0.20%
SpecificHeatCapacity of Melt内部方法1600J/kg/°C
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulusISO527-2/1A/119000Mpa
Tensile strengthBreak,23°CASTMD638131Mpa
Tensile stressBreakISO527-2/1A/5130Mpa
elongationBreak,23°CASTMD6381.3%
Tensile strainBreakISO527-2/1A/51.2%
Tensile modulusISO 527-119000Mpa
tensile strength ISO 527-1130Mpa
elongationBreakISO 527-11.2%
Bending modulusISO 17818800Mpa
bending strength ISO 178210Mpa
IZOD notch impact strength23℃ISO 180/1A6kJ/m²
Rockwell hardnessISO 294-4100M-scale
Bending modulus23°CISO17818800Mpa
Bending stress 2ISO178210Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature1.80MpaISO 75-1270°C
Flame retardant grade0.750mmUL94V-0
Hot deformation temperature0.45MPa,AnnealedASTMD648280°C
Hot deformation temperature1.8MPa,UnannealedASTMD648266°C
Hot deformation temperature1.8MPa,UnannealedISO75-2/A270°C
Hot deformation temperature8.0MPa,UnannealedISO75-2/C215°C
Glass transition temperature 3ISO11357-290.0°C
Melting temperature 5ISO11357-3280°C
Linear coefficient of thermal expansionMDISO11359-21.9E-05cm/cm/°C
Linear coefficient of thermal expansionTDISO11359-22.4E-05cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface resistivityIEC60093>1.0E+15ohms
Leakage Trace IndexIEC60112175V
Volume resistivityASTMD2571E+16ohms·cm
Volume resistivityIEC60093>1.0E+17ohms·cm
Dielectric strengthIEC60243-125KV/mm
Dielectric constant1kHzASTMD1505.40
Dielectric constant1MHzASTMD1505.60
Relative permittivity1MHzIEC602505.60
Dissipation factor1kHzASTMD1501E-03
Dissipation factor1MHzASTMD1509E-04
Dissipation factor1MHzIEC602502E-03
Arc resistanceASTMD495182sec
Impact performanceTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength -30°CISO179/1eA7.0kJ/m²
Charpy Notched Impact Strength 23°CISO179/1eA7.0kJ/m²
Impact strength of simply supported beam without notch-30°CISO179/1eU20kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eU20kJ/m²
Impact strength of cantilever beam gap-30°CISO180/1A6.0kJ/m²
Impact strength of cantilever beam gap23°CISO180/1A6.0kJ/m²
Unscented Izod impact strength23°CISO180/1U20kJ/m²
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessM-ScaleASTMD785100
Rockwell hardnessM-ScaleISO2039-2100
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating0.75mmUL94V-0
UL flame retardant rating1.5mmUL94V-0
UL flame retardant rating3.0mmUL945VA
Extreme Oxygen IndexISO4589-253%
Basic performanceTest ConditionTest MethodTest ResultUnit
Water absorption rate23℃ISO 620.02%
Supplementary InformationTest ConditionTest MethodTest ResultUnit
SpecimensThickness Shrinkage内部方法3.18mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.