physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | MD | 内部方法 | 0.17 | % |
Shrinkage rate | TD | 内部方法 | 0.40 | % |
Water absorption rate | Saturation | ASTMD570 | 0.020 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
elongation | Break | ASTMD638 | 4.5 | % |
Bending modulus | 23°C | ASTMD790 | 12500 | Mpa |
bending strength | Yield,23°C | ASTMD790 | 140 | Mpa |
shear strength | | ASTMD732 | 54.0 | Mpa |
Tensile strength | Yield | ASTMD638 | 130 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 270 | °C |
Linear coefficient of thermal expansion | MD:150°C | 内部方法 | 4E-06 | cm/cm/°C |
Linear coefficient of thermal expansion | TD:150°C | 内部方法 | 8.1E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Leakage Trace Index | | IEC60112 | 190 | V |
Dissipation factor | 1MHz | ASTMD150 | 0.038 | |
Dissipation factor | 1.00GHz | ASTMD150 | 4E-03 | |
Dielectric constant | 1MHz | ASTMD150 | 3.80 | |
Dielectric constant | 1.00GHz | ASTMD150 | 3.60 | |
Arc resistance | | ASTMD495 | 140 | sec |
Volume resistivity | | ASTMD257 | 1E+15 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Cantilever beam without notch impact strength | 6.40mm | ASTMD256 | 270 | J/m |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | R-Scale | ASTMD785 | 97 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.30mm,NC,BK | UL94 | V-0 | |
Extreme Oxygen Index | | ISO 489 | 44 | % |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|
Soldering | | 内部方法 | 280 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.