physical property | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate | 24 hr | ASTM D570 | 0.15 | % |
Water absorption rate | Equilibrium, 23°C | ASTM D570 | 0.35 | % |
Water absorption rate | Equilibrium, 100°C | ASTM D570 | 0.58 | % |
Specific volume | | ASTM D792 | 0.830 | cm³/g |
Outdoor applicability | | UL 746C | f1 | |
Melt flow rate | 300°C/1.2 kg | ASTM D1238 | 18 | g/10 min |
Shrinkage rate - flow | 3.20 mm | 内部方法 | 0.50 到 0.70 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile strength 2 | Yield | ASTM D638 | 62.0 | Mpa |
Tensile strength 2 | Break | ASTM D638 | 65.0 | Mpa |
Elongation rate 2 | Yield | ASTM D638 | 7.0 | % |
Elongation rate 2 | Break | ASTM D638 | 110 | % |
Bending modulus | 50.0 mm Span | ASTM D790 | 2340 | Mpa |
bending strength | Yield, 50.0 mm Span | ASTM D790 | 93.0 | Mpa |
Taber abraser | 1000 Cycles, 1000 g, CS-17 Wheel | ASTM D1044 | 10.0 | mg |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
specific heat | | ASTM C351 | 1260 | J/kg/°C |
thermal conductivity | | ASTM C177 | 0.25 | W/m/K |
RTI | | UL 746 | 100 | °C |
RTI Imp | | UL 746 | 100 | °C |
RTI Elec | | UL 746 | 100 | °C |
Thermal deformation temperature under load | 0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 137 | °C |
Thermal deformation temperature under load | 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 132 | °C |
Linear coefficient of thermal expansion - flow | -40 to 95°C | ASTM E831 | 6.8E-5 | cm/cm/°C |
Vicat softening temperature | | ASTM D15257 | 154 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
High arc combustion index (HAI) 8 | | UL 746 | PLC 1 | |
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | PLC 2 | |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 2 | |
Hot wire ignition (HWI) | | UL 746 | PLC 4 | |
Dielectric constant | 60 Hz | ASTM D150 | 3.17 | |
Dielectric constant | 50 kHz | ASTM D150 | 3.17 | |
Dielectric constant | 1 MHz | ASTM D150 | 2.96 | |
Volume resistivity | | ASTM D257 | > 1.0E+17 | ohms·cm |
Dissipation factor | 50 Hz | ASTM D150 | 9.0E-4 | |
Dissipation factor | 60 Hz | ASTM D150 | 9.0E-4 | |
Dissipation factor | 1 MHz | ASTM D150 | 0.010 | |
Dielectric strength | 3.20 mm, in Air | ASTM D149 | 15 | KV/mm |
injection | Test Condition | Test Method | Test Result | Unit |
---|
drying time | | | 3.0 到 4.0 | hr |
Suggested injection volume | | | 40 到 60 | % |
Temperature at the rear of the barrel | | | 260 到 280 | °C |
Temperature in the middle of the barrel | | | 270 到 295 | °C |
Temperature at the front of the material cylinder | | | 280 到 305 | °C |
Spray nozzle temperature | | | 275 到 300 | °C |
Back pressure | | | 0.300 到 0.700 | Mpa |
Screw speed | | | 40 到 70 | rpm |
Exhaust hole depth | | | 0.025 到 0.076 | mm |
drying temperature | | | 120 | °C |
Suggested maximum moisture content | | | 0.020 | % |
Processing (melt) temperature | | | 280 到 305 | °C |
Mold temperature | | | 70 到 95 | °C |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Falling hammer impact | 23°C | ASTM D3029 | 169 | J |
Non notched cantilever beam impact | 23°C | ASTM D4812 | 3200 | J/m |
Non notched cantilever beam impact | -30°C 5 | ISO 180/1U | 无断裂 | |
Non notched cantilever beam impact | 23°C 5 | ISO 180/1U | 无断裂 | |
Tensile impact strength 6 | | ASTM D1822 | 546 | kJ/m² |
Impact strength of simply supported beam gap 4 | -30°C | ISO 179/1eA | 12 | kJ/m² |
Impact strength of simply supported beam gap 4 | 23°C | ISO 179/1eA | 65 | kJ/m² |
Simple supported beam without notch impact strength 4 | -30°C | ISO 179/1eU | 无断裂 | |
Simple supported beam without notch impact strength 4 | 23°C | ISO 179/1eU | 无断裂 | |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | M-Scale | ASTM D785 | 70 | |
Rockwell hardness | R-Scale | ASTM D785 | 118 | |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Refractive index | | ASTM D542 | 1.586 | |
Haze | 2540 µm | ASTM D1003 | 1.0 | % |
transmissivity | 2540 µm | ASTM D1003 | 88.0 | % |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.75 mm | UL 94 | V-2 | |
UL flame retardant rating | 6.0 mm | UL 94 | V-0 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.