Technical Data Sheet
Compare
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | 干 | 旭化成方法 | 0.5/0.9 | % |
Wear rate | 湿 | ASTM D-1044 | 12 | ×10-6kg/1000times |
Shrinkage rate | TD | 内部方法 | 0.90 | % |
Shrinkage rate | MD | 内部方法 | 0.50 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Flexural strength | 干(湿) | ASTM D-790 | 290(175) | Mpa |
Cantilever beam notch impact strength | 干(湿) | ASTM D-256 | 105(160) | J/m |
tensile strength | 干(湿) | ASTM D-638 | 180(110) | Mpa |
Fracture elongation rate | 干(湿) | ASTM D-638 | 3(6) | % |
Scratch resistance coefficient | 干(湿) | ASTM D-790 | 8.1(4.7) | GPa |
Rockwell hardness | 干(湿) | ASTM D-785 | 96(74) | M Scale |
Rockwell hardness | 干(湿) | ASTM D-785 | 120(-) | R scale |
bending strength | | ASTMD790 | 290 | Mpa |
Bending stress | 23°C | ISO178 | 275 | Mpa |
Tensile modulus | 23°C | ISO527-2 | 8200 | Mpa |
Tensile strength | | ASTMD638 | 180 | Mpa |
Tensile stress | Break,23°C | ISO527-2 | 190 | Mpa |
elongation | Break | ASTMD638 | 3.0 | % |
Tensile strain | Break,23°C | ISO527-2 | 4.0 | % |
Bending modulus | | ASTMD790 | 8100 | Mpa |
Bending modulus | 23°C | ISO178 | 7800 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 0.45MPa,Unannealed | ASTMD648 | 260 | °C |
Hot deformation temperature | 0.45MPa,Unannealed | ISO75-2/B | 260 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 250 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 245 | °C |
Linear coefficient of thermal expansion | MD | ASTMD696 | 3E-05 | cm/cm/°C |
thermal conductivity | | | 0.30 | W/m/K |
Hot deformation temperature | 1.82MPa,干 | ASTM D-648 | 250 | °C |
Thermal conductivity | 干 | | 0.3 | W/(m.K) |
Linear expansion coefficient | 干 | ASTM D-696 | 3 | ×10-5/K |
Hot deformation temperature | 0.46MPa,干 | ASTM D-648 | 260 | °C |
Flame retardancy | 干 | UL 94 | HB | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric strength | | ASTMD149 | 29 | KV/mm |
Dielectric strength | | IEC60243-1 | 29 | KV/mm |
Leakage Trace Index | 3.00mm | IEC60112 | 600 | V |
Surface resistivity | | ASTMD257 | 1E+15 | ohms |
Surface resistivity | | IEC60093 | 1E+15 | ohms |
Volume resistivity | | ASTMD257 | 1E+15 | ohms·cm |
Volume resistivity | 23°C | IEC60093 | 1E+15 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | | ISO179 | 68 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | M-Sale | ASTMD785 | 96 | |
Rockwell hardness | R-Sale | ASTMD785 | 120 | |
Rockwell hardness | M-Sale | ISO2039-2 | 96 | |
Rockwell hardness | R-Sale | ISO2039-2 | 120 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
FlameRating | 0.75mm | UL94 | HB | |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Moisture absorption rate | 湿 | | 1.9 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.