PA6 M2400 GUANGDONG XINHUI MEIDA
125
- Unit Price:
- $2052 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 299.5MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:--
- Application Areas:Short fiber Textile application
- Color:--
- Grade:Wire drawing grade
Technical Data Sheet
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | ASTM D-638 | 2142.0 | Mpa | |
bending strength | ASTM D-790 | 112.8 | Mpa | |
elongation | Break | ASTM D-638 | 71.0 | % |
Gap impact strength | ASTM D-256 | 10.0 | kJ/m² | |
tensile strength | ASTM D 638 | 70.5 | Mpa | |
Bending modulus | ASTM D-790 | 1971.9 | Mpa | |
Brinell hardness | ASTM D-785 | 17.4 | Kgf/mm2 |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 1.82MPa | ASTM D-648 | 54 | °C |
combustion performance | UL94 | V2 | ||
Melt index | ASTM D-1238 | 26.0 | g/10min |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric loss tangent | ASTM D-150 | 0.030 | MHz | |
Dielectric constant | ASTM D-150 | 3.2 | MHz |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Relative viscosity | GB T1632-93 | 2.45 | ||
Monomer content | ≤0.5 | % | ||
density | GB 1033-86 | 1.14 | g/cm³ | |
Shrinkage rate | 1.3 | % | ||
water content | ≤0.05 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.