Technical Data Sheet
Compare
Physical properties | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate 23 ℃/24h | | ASTM D570/ISO 62 | 10.5 | % |
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate of molded products | | | 0.4-0.7 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
bending strength | | ISO 178 | 32 | Mpa |
Impact strength of cantilever beam gap | 23℃ | ISO 180 | 10 | kJ/m² |
Rockwell hardness | | ASTM D-785 | 70 | L标尺 |
Rockwell hardness | | ASTM D785 | 70 | |
bending strength | | ASTM D790/ISO 178 | 32 | kg/cm²(MPa)[Lb/in²] |
Shear beam notch impact strength | 23℃ | ISO 179/1eA | 11 | kJ/m² |
Tensile yield stress | | ISO 527 | 21 | Mpa |
Tensile strain at break | | ISO 527 | 40 | % |
Tensile elongation at break (elongation at break) | | ASTM D638/ISO 527 | 40 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
vicat softening point | | ASTM D1525/ISO R306 | 90 | ℃(℉) |
Hot deformation temperature | | ISO 75 | 88 | °C |
Flame retardancy | | UL 94 | HB | |
vicat softening point | | ISO 306 | 90 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume resistivity | | IEC6093 | >1014 | Ω.cm |
Processing performance | Test Condition | Test Method | Test Result | Unit |
---|
Injection molding melt temperature | | | 180-260 | °C |
Extrusion molding melt temperature | | | 180-240 | °C |
Injection molding mold temperature | | | 10-60 | °C |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate | | ISO 62 | <0.1 | % |
density | | ISO 1183 | 1.05 | g/cm³ |
Melt index | | ISO 1133 | 3.2 | cm3/10min |
Other performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile modulus of elasticity | | ISO 527 | 1600 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.