Material Description
Technical Data Sheet

Material Description

  • Material Properties:High mobility High gloss High impact resistance Medium impact good flow
  • Application Areas:Office supplies Household appliances Automotive sector
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
densityASTMD7921.04g/cm³
densityISO11831.04g/cm³
Melt mass flow rate200°C/21.6kgASTMD123838g/10min
Melt mass flow rate220°C/10.0kgASTMD123838g/10min
Melt mass flow rate220°C/10.0kgISO113338g/10min
Shrinkage rateMDASTMD9550.50to0.80%
Shrinkage rateISO294-40.50to0.80%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile strength屈服ASTMD63847.6Mpa
Tensile stress屈服ISO527-246.0Mpa
elongation屈服ASTMD63815%
Tensile strain断裂ISO527-220%
Bending modulusASTMD7902400Mpa
Bending modulusISO1782500Mpa
Bending stressISO17873.0Mpa
bending strength 屈服ASTMD79070.6Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature0.45MPa,未退火ISO75-2/B91.0°C
Hot deformation temperature1.8MPa,未退火ASTMD64885.0°C
Hot deformation temperature1.8MPa,未退火ISO75-2/A80.0°C
Vicat softening temperatureASTMD1525295.0°C
Vicat softening temperatureISO306/B5095.0°C
Impact performanceTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength 23°CISO179/1eA22kJ/m²
Impact strength of cantilever beam gap23°C,3.20mmASTMD256240J/m
Impact strength of cantilever beam gap23°C,6.40mmASTMD256200J/m
Impact strength of cantilever beam gap23°CISO180/1A21kJ/m²
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.