Need Help? Contact Us service@plas.com
Get App

PC LEXAN™  HPX4 1H8A005T SABIC INNOVATIVE US

117
  • Unit Price:
    $5266 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    36.3MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Middle flow Biocompatibility Steam sterilization
  • Application Areas:Drug application Medical and nursing suppl Medical devices
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Water absorption rateEquilibrium,23°C,50%RHISO620.093%
Melt mass flow rate300°C/1.2kgASTMD123810g/10min
Melt volume flow rate300°C/1.2kgISO11339.50cm3/10min
Shrinkage rateMD:3.20mm内部方法0.40to0.80%
Shrinkage rateTD:3.20mm内部方法0.40to0.80%
Water absorption rateSaturation,23°CISO620.12%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulus 2ASTMD6382220Mpa
Tensile modulusISO527-2/12350Mpa
Tensile strength 3YieldASTMD63858.0Mpa
Tensile stressYieldISO527-2/5057.9Mpa
Tensile strength 3BreakASTMD63864.1Mpa
Tensile stressBreakISO527-2/5061.5Mpa
Elongation rate 3YieldASTMD6385.8%
Tensile strainYieldISO527-2/505.5%
Elongation rate 4BreakASTMD638130%
Tensile strainBreakISO527-2/50120%
Bending modulus 450.0mmSpanASTMD7902220Mpa
Bending modulus 5ISO1782150Mpa
Bending strength 5,6ISO17890.2Mpa
Bending strength 4Yield,50.0mmSpanASTMD79094.3Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature1.8MPa,Unannealed,3.20mmASTMD648124°C
Hot deformation temperature 91.8MPa,Unannealed,64.0mmSpanISO75-2/Af119°C
Vicat softening temperatureASTMD152510141°C
Vicat softening temperature--ISO306/B50141°C
Vicat softening temperature--ISO306/B120142°C
BallPressure Test125°CIEC60695-10-2Pass
Linear coefficient of thermal expansionMD:-40to95°CASTME8317.2E-05cm/cm/°C
Linear coefficient of thermal expansionMD:23to80°CISO11359-27.2E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-40to95°CASTME8317.9E-05cm/cm/°C
Linear coefficient of thermal expansionTD:23to80°CISO11359-27.9E-05cm/cm/°C
RTIElecUL746130°C
RTIStrUL746130°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface resistivityASTMD257>1.0E+15ohms
Volume resistivityASTMD257>1.0E+15ohms·cm
Impact performanceTest ConditionTest MethodTest ResultUnit
Impact strength of simply supported beam gap 7-30°CISO179/1eA55kJ/m²
Impact strength of simply supported beam gap 723°CISO179/1eA65kJ/m²
The impact strength of a simply supported beam without a notch is 7-30°CISO179/1eUNoBreak
The impact strength of a simply supported beam without a notch is 723°CISO179/1eUNoBreak
Suspended wall beam gap impact strength 8-30°CISO180/1A55kJ/m²
Suspended wall beam gap impact strength 823°CISO180/1A65kJ/m²
Unscented Izod Impact Strength 8-30°CISO180/1UNoBreak
Unscented Izod Impact Strength 823°CISO180/1UNoBreak
Dart impact equipped with measuring instruments-30°C,TotalEnergyASTMD376385.0J
Dart impact equipped with measuring instruments23°C,TotalEnergyASTMD376382.4J
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessL-SaleASTMD78590
optical performance Test ConditionTest MethodTest ResultUnit
transmissivity2540µmASTMD100382.0%
Haze2540µmASTMD10033.0%
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating2.5mmUL94V-2
Burning wire flammability index3.0mmIEC60695-2-12960°C
Hot filament ignition temperature0.8mmIEC60695-2-13825°C
Hot filament ignition temperature3.0mmIEC60695-2-13825°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.