PPA Amodel® PPA AT-1116HSNT SOLVAY USA
118
- Unit Price:
- $10292 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 10MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Chemical resistance Dimensional stability High temperature resistan
- Application Areas:Industrial components Connector Car hood Spool bearing
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | Across Flow | ASTM D955 | 0.6 | % |
Flow | ASTM D955 | 0.6 | % | |
Water absorption rate | 23H | ASTM D570 | 0.20 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile stress | ASTM D527-2 | 131 | Mpa | |
tensile elongation | break | ASTM D638 | 2.8 | % |
No notch impact strength | ASTM D256 | 801 | J/m | |
Gap impact strength | ASTM D256 | 48 | J/m | |
Charpy notch impact strength | 23℃ | ISO 179/1eA | 9 | kJ/m² |
23℃ | ISO 179/1eU | 86 | kJ/m² | |
Tensile modulus | ASTM D638 | 7100 | Mpa | |
Bending modulus | ASTM D790 | 6210 | Mpa | |
bending strength | ASTM D790 | 201 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 0.45MPa,Annealed | ASTM D648 | 268 | °C |
1.8MPa,Annealed | ASTM D648 | 254 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.