Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.2 | |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 0.2 | % |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Transmittance | 厚度3mm | ASTM D-1003 | 88 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Izod Impact Strength | 艾氏、带Notched厚度3.2mm | ASTM D-256 | 830(85) | j/m(kgf.cm/cm) |
Notched Izod Impact Strength | 艾氏、带Notched厚度6.4mm | ASTM D-256 | 130(13) | j/m(kgf.cm/cm) |
Elongation rate | Yield点,- | ASTM D-638 | 6 | - |
Elongation rate | Break点,- | ASTM D-638 | 140 | - |
Compressive Strength | | ASTM D-695 | 76(780) | MPa(Kgf/cm |
Tensile Modulus | | ASTM D-638 | 2130(21700) | MPa(Kgf/cm |
Tensile Modulus | | ASTM D638/ISO 527 | 2130 | kg/cm²(MPa)[Lb/in²] |
Tensile Strength | Yield点,- | ASTM D-638 | 62(630) | MPa(Kgf/cm |
Tensile Strength | Break点,- | ASTM D-638 | 78(800) | MPa(Kgf/cm |
Tensile Elongation | | ASTM D638/ISO 527 | 6 | % |
Rockwell Hardness | | ASTM D785 | 77 | |
Rockwell Hardness | | ASTM D-785 | 77 | M标度 |
Flexural Modulus | | ASTM D-790 | 2260(23000) | MPa(Kgf/cm |
Flexural Strength | | ASTM D-790 | 90(920) | MPa(Kgf/cm |
Flexural Strength | | ASTM D790/ISO 178 | 90 | kg/cm²(MPa)[Lb/in²] |
Refractive index of light | | ASTM D-542 | 1.585 | |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 140 | % |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Linear expansion coefficient | | ASTM D696/ISO 11359 | 7 | mm/mm.℃ |
Temperature Index | 电学式,厚度1.47mm | UL 746B | 125 | °C |
Temperature Index | 冲击式,厚度1.47mm | UL 746B | 115 | °C |
Temperature Index | 非冲击式,厚度1.47mm | UL 746B | 125 | °C |
Heat Deflection Temperature | 负荷0.451MPa(4.6kgf/cm) | ASTM D-648 | 142 | °C |
Heat Deflection Temperature | 负荷1.813MPa(18.6kgf/cm) | ASTM D-648 | 132 | °C |
Coefficient of Linear Thermal Expansion | Flow (Across Flow ) | ASTM D-696 | 7 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dissipation Factor (Tangent) | 60Hz(10 | ASTM D-150 | 0.0004(0.009) | |
Comparative Tracking Index | | IEC 112 | 300 | V |
Dielectric Constant | 60Hz(10 | ASTM D-150 | 2.95(2.9) | |
Insulation failure strength | 快速加压值厚度1.6mm | ASTM D-149 | 30 | KV/mm |
Arc Resistance | | ASTM D-495 | 110 | sec |
Arc Resistance | | ASTM D495/IEC 60112 | 110 | |
Volume Resistivity | | ASTM D-257 | 3 | |
Processing | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Flow ,- | ASTM D-955 | 0.5~0.7 | % |
Modeling Shrinkage | Across Flow ,- | ASTM D-955 | 0.5~0.7 | % |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Transmittance | | ASTM D1003/ISO 13468 | 88 | % |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24hr,in 23℃ | ASTM D-570 | 0.20 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.